Updated on 2022-02-24 GMT+08:00

Historical Device Data Query

Typical Scenario

The IoT platform receives and saves service data reported by devices during daily operation. The storage duration of device data can be configured by calling the API for modifying device information and the device data can be stored for a maximum of 90 days. If an NA needs to view the historical data reported by a device to the IoT platform, the NA can call this API to obtain the data.

API Function

This API is used by an NA to query historical data reported by a specified device to the IoT platform based on the device ID.

API Description

1
QueryDeviceDataHistoryOutDTO queryDeviceDataHistory(QueryDeviceDataHistoryInDTO qddhInDTO, String accessToken) throws NorthApiException

Parameter Description

Parameter

Mandatory or Optional

Type

Location

Description

qddhInDTO

Mandatory

QueryDeviceDataHistoryInDTO structure

query

For details, see QueryDeviceDataHistoryInDTO structure.

accessToken

Mandatory

String

header

If the Periodically Refreshing a Token API is called, set this parameter to null. Otherwise, set this parameter to the accessToken obtained by the Authentication API.

QueryDeviceDataHistoryInDTO structure

Parameter

Mandatory or Optional

Type

Location

Description

appId

Mandatory

String

query

If the device belongs to the current application, set this parameter to null. Otherwise, set this parameter to the ID of the authorized application.

deviceId

Mandatory

String

query

Identifies a device.

gatewayId

Mandatory

String

query

Identifies a gateway.

serviceId

Optional

String

query

Identifies a service.

property

Optional

String

query

Indicates the service attribute.

pageNo

Optional

Integer

query

Indicates the page number.

  • If the value is null, pagination query is not performed.
  • If the value is an integer greater than or equal to 0, pagination query is performed.
  • If the value is 0, the first page is queried.

pageSize

Optional

Integer

query

Indicates the number of records on each page. The default value is 1.

startTime

Optional

String

query

Indicates the start time. Historical shadow data generated later than the specified start time is queried. The value is in the format of yyyyMMdd'T'HHmmss'Z'. An example value is 20151212T121212Z.

endTime

Optional

String

query

Indicates the end time. Historical shadow data generated earlier than the specified end time is queried. The value is in the format of yyyyMMdd'T'HHmmss'Z'. An example value is 20151212T121212Z.

Response Parameters

QueryDeviceDataHistoryOutDTO

Parameter

Type

Description

totalCount

Long

Indicates the number of queried records.

pageNo

Long

Indicates the page number.

pageSize

Long

Indicates the number of records on each page.

deviceDataHistoryDTOs

List<DeviceDataHistoryDTO>

Indicates the historical device data list. For details, see DeviceDataHistoryDTO structure.

DeviceDataHistoryDTO structure

Parameter

Type

Description

serviceId

String(256)

Identifies a service.

deviceId

String(256)

Identifies a device.

gatewayId

String(256)

Identifies a gateway. The gateway ID is the same as the device ID if the device is a directly connected device. If the device is a non-directly connected device, the gateway ID is the device ID of the directly connected device (that is, the gateway) with which it associates.

appId

String(256)

Uniquely identifies an NA.

data

JsonObject

Indicates the data reported by the device.

timestamp

String(256)

Indicates the timestamp when the data is reported. The value is in the format of yyyyMMdd'T'HHmmss'Z'. An example value is 20151212T121212Z.

Error Codes

HTTP Status Code

Error Code

Error Description

Remarks

200

100418

The deviceData is not existed.

The device data does not exist.

Recommended handling:

  • If deviceId carried in the request is incorrect, check whether deviceId belongs to appId or whether deviceId is incorrect.
  • Check whether appId carried in the header contains deviceId.
  • If the URL contains the optional parameter appId, check whether the value of appId is correct.

400

100216

The application input is invalid.

The application input is invalid.

Recommended handling: Check whether parameters in the API request are correct by referring to the request parameter description. For example, check whether the value of pageSize exceeds 2000.

400

100419

The deviceId and gatewayId can't be both null.

The deviceId and gatewayId parameters cannot be null at the same time.

Recommended handling: Check whether deviceId or gatewayId is set.

403

100203

The application is not existed.

The application does not exist.

Recommended handling:

  • Check whether appId carried in the HTTP request header is correct.
  • Check whether appId in the request path (URL) is correct.

403

100217

The application hasn't been authorized.

The application has not been authorized.

Recommended handling: In scenarios where applications are not authorized, ensure that request parameter appId is null.

403

1010009

app throttle exceed.

The NA calls the API at a frequency that exceeds the flow control threshold (100 calls per minute by default).

Recommended handling: Contact IoT platform maintenance personnel to adjust the flow control threshold or control the API call frequency.

403

1010005

App_key or access_token is invalid.

The access token is invalid.

Recommended handling: Check whether accessToken carried in the API request is correct.

500

100203

The application is not existed.

The application does not exist.

Recommended handling:

  • Check whether appId carried in the HTTP request header is correct.
  • Check whether appId in the request path (URL) is correct.

500

50252

Internal server error.

An internal server error occurs.

Recommended handling: An internal error occurs on the IoT platform. Contact IoT platform maintenance personnel.